Flow Computer GDR 1540

GDR1501

The 1-channel flow computer/ volume corrector GDR 1540 is used to calculate the current gas volume of gas flow meters with a Namur output.

HIGHLIGHTS

  • 4-line display with 20 characters per line

  • Multilingual menu (English, German, French, Spanish, Italian, Bulgarian, Polish, …)

  • Complete device configuration via keypad, no additional software required

  • Integrated WLAN hotspot with full device access via web browser

  • Security code to protect configuration

  • Timestamped logging of important actions in the system logbook (device start, sensor failure, overrange, etc.)

  • Easy and fast cable connection with tool-free connectors 

  • UV-resistant polycarbonate housing material, protection class IP 65

  • Persistent counter readings for up to 5 years

  • Integrated real-time clock,
    battery buffered for 5 years

  • Standardization according to DIN 1343, DIN 6358, DIN ISO 2533, DIN 102/ISO 1-1975

  • Freely scalable current output for output of actual flow rate

  • Adjustable pulse weighting
    (0.1, 1 or 10 or 100 m³ per pulse)

  • Optional data transmission via Modbus RTU and Modbus TCP 

DESCRIPTION

The 1-channel flow computer/ volume corrector GDR 1540 is used to calculate the current gas volume of gas flow meters with a Namur output.

On an hourly or minutely basis, the current gas quantity can be displayed in cubic meters or liters. The total counter reading can be displayed in cubic meters or liters. The counter can have 9 digits up to 999 million cubic meters. The resolution is 0.1 liters.

Based on the operating volume determined by the connected gas flow meter and the measured values for pressure and temperature, the volume corrector calculates the standardized volume. The calculation of the standardization can be done according to the standards DIN 1343, DIN 6358, DIN ISO 2533 or DIN 102/ ISO 1-1975.

Inputs: Gas flow meter

1. Namur input (2-fold)

Inputs: Pressure and temperature

In addition to a pt100 input, the devices also have mA inputs for pressure and temperature sensors as well as an integrated barometric sensor for recording atmospheric pressure.

Output and bus system

The 0(4) – 20 mA current output provides the current flow rate in the form of operating or standard cubic meters. Via 2 solid state relays, flow rates, device status, error messages or limit values can be transmitted to higher-level systems for further processing. 

The Modbus RTU and Modbus TCP bus systems are available as an option for data transmission. 

All parameter settings/configurations can be carried out using the keys and the display or with a web browser via the integrated WLAN hotspot.